Header bg
  • Users Online: 314
  • Print this page
  • Email this page
Header bg
ORIGINAL ARTICLE
Year : 2020  |  Volume : 4  |  Issue : 1  |  Page : 3-7

Comparison the effect of preloading and coloading with crystalloid fluid on the incidence of hypotension after spinal anesthesia in cesarean section


1 Department of Anesthesiology and Intensive Care, Faculty of Medicine, Nusa Cendana University - Prof. Dr. W. Z. Johannes General Hospital, Kupang, Indonesia
2 Department of Public Health and Community Medicine, Faculty of Medicine, Nusa Cendana University, Kupang, Indonesia

Correspondence Address:
Dr. I Made Artawan
M. Biomed., Sp. An, Department of Anesthesiology and Intensive Care, Faculty of Medicine, Nusa Cendana University, Adisucipto Street, Penfui, Kupang, East Nusa Tenggara 85228, Tenggara
Indonesia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/BJOA.BJOA_17_19

Rights and Permissions

Introduction: Hypotension after spinal anesthesia is a frequent complication in patients undergoing cesarean section; the incidence of maternal hypotension is 60%–70%. One way to overcome or prevent hypotension due to spinal anesthesia is by administering intravenous fluid boluses. This study was conducted with the aim of comparing the effectiveness of crystalloid fluid preloading and coloading against the incidence of hypotension after spinal anesthesia in cesarean section. Methods: This research is a single-blind clinical trial. The number of subjects who participated in this study were 51 subjects. Subjects selected by consecutive sampling with inclusion criteria gravida patients aged 16 years to 40 years with ASA 1 or ASA 2 physical status who would undergo elective cesarean section with spinal anesthesia and there were no contraindications for spinal anesthesia. Participants were divided into three groups, namely preloading group, coloading group, and control group. Systolic blood pressure, diastolic blood pressure, mean arterial pressure (MAP), and pulse rates are measured in basal conditions and 1, 2, 4, 6, 8, 10, 15, 20, 25, and 30 min after spinal anesthesia. Statistical analysis for the differences in hemodynamic parameters among the three groups of subjects were analyzed by the Repeated Measured Multivariate Analysis of Variance (MANOVA) test. Whereas Bonferonni post hoc test was used to compare the differences in hemodynamic parameters between each group. Results: Bonferroni post hoc test results showed that there were significant differences in the decrease of systolic, diastolic, and MAP blood pressure differences between the coloading group with the preloading group and the control group (P < 0.001); the lowest decrease was in the coloading group. Conclusion: Crystalloid fluid coloading was significantly better in reducing hypotension incidence after spinal anesthesia in cesarean section compared with the preloading and control groups.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed6193    
    Printed167    
    Emailed2    
    PDF Downloaded472    
    Comments [Add]    
    Cited by others 1    

Recommend this journal